Design & Planning
The performance, longevity, and sustainability of a data center are defined by the engineering decisions made during the planning stage.
Infitek views design as a strategic engineering phase that determines operational efficiency and future readiness. Each project is approached according to real on-site conditions, customer priorities, and international compliance standards.
Every component is designed in accordance with TIA-942, BICSI, ASHRAE, ISO 27001, EN 50600, and Uptime Institute Tier standards.
The goal is not only to meet current needs but also to create scalable and modular infrastructures ready for future capacity growth. From white space layouts to power distribution, cable pathways to cooling scenarios, every detail is digitally modeled and validated.
Through CFD (Computational Fluid Dynamics) analysis, airflow performance, power usage effectiveness (PUE), and thermal mapping are simulated — ensuring system optimization from the earliest design phase.
Site Survey and Preliminary Analysis
- On-site inspections and assessment of existing infrastructure
- Power capacity, redundancy, and load analysis (N, N+1, 2N scenarios)
- Cooling capacity calculations and airflow measurements
- Review of existing structured cabling topology
Infrastructure Planning
- White space layout design and cabinet arrangement (Hot/Cold Aisle optimization)
- Fiber and copper cabling topology, pathway design, and floor penetration plans
- Planning of F/O channels, wire mesh trays, ladders, and cable support systems
- Layout of power panels, UPS, busbar, grounding, and distribution boards
- Configuration of redundancy and dual-feed power paths
- Energy efficiency scenarios aligned with PUE targets
Mechanical and Cooling Design
- Cooling capacity planning and airflow modeling
- CRAC/CRAH placement and containment system selection
- Air pressure balance and temperature distribution simulations
- CFD analysis and thermal performance reporting
- Fire detection, suppression, and sensor layout planning
Electrical and Power Systems
- Power distribution and UPS system architecture
- UPS topology and power continuity analysis
- Generator circuits and synchronization design
- Power analyzers, grounding, and potential equalization systems
- Busbar line design and modular power feed planning
Monitoring and Management Systems
- DCIM (Data Center Infrastructure Management) architecture
- BMS (Building Management System) and PMS (Power Management System) planning
- Integration of alarm, sensor, environmental monitoring, and access systems
- CCTV, IP camera, video wall, and physical security design
Documentation and Standards
- Single-line diagrams, connection schematics, and labeling plans
- Drawings compliant with TIA-942, BICSI, Uptime Tier, ISO, and EN 50600
- Project reports, BoQ (Bill of Quantities), and workflow documentation
- Client presentation packages, approval files, and revision management
Why Infitek?
- Seamless integration of all systems in full compliance with global standards
- Scalable, modular, and energy-efficient infrastructure design
- Optimized performance through CFD and energy analysis
- Architectures aligned with Uptime Tier objectives
- Reduced installation and operational costs through accurate planning
- Full traceability with standard-compliant documentation